<x-flowed>
This should be on Rasterlist (rasterlist@synthcom.com)....but I would check
that you do not have a primary rectifier diode that is shorted. This often
happens if someone forgot to use an isolation transformer...
John :-#)#
At 06:55 PM 10/02/2003 -0500, Christopher X. Candreva wrote:
>Next person who says that is going to get . . .
>
>I'm fixing my first raster monitor -- a G07, and it comes time to check the
>chasis mounted transistors. Bob Robert's tips page has all this talk about
>soldering on them, and I'm saying to myself "Why is anyone resoldering on
>the socket. I mean, T03 transistors are socketed, right ?"
>
>Great Mother of Zeus -- they solder wires right on the transistors ! NO
>SOCKETS !!!!
>
>Oh give me my vector monitors with nice clean plugs, sockets, etc, any day.
>
>-Chris
>
>PS -- anyone who knows why a G07 would be blowing the 1.25 amp fuse when the
>chasis transistors are NOT shorted to ground, the heater coil isn't shorted
>to ground, and the flyback isn't cracked, I'm open to suggestions at this
>point.
>
>==========================================================
>Chris Candreva -- chris@westnet.com -- (914) 967-7816
>WestNet Internet Services of Westchester
>http://www.westnet.com/
>---------------------------------------------------------------------------
>** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
>** message body to vectorlist-request@synthcom.com. Please direct other
>** questions, comments, or problems to vectorlist-owner@synthcom.com.
</x-flowed>
Received on Tue Feb 11 10:39:13 2003