Re: ESR meter construction question

From: John Robertson <jrr_at_flippers.com>
Date: Fri Jan 21 2000 - 11:17:05 EST

<x-flowed>Have you tried using a jumper wire to short out the input jacks? I find the
quality of probes varies greatly...

Do you get the correct resistance values with the two test resistors? 86R
and some other resistor...

John :-#)#

At 08:44 AM 1/21/2000 -0500, you wrote:

>I finally built my ESR meter kit from John and it "works" (it powers up,
>displays "EA" and then "- ") but when the measurement leads are tied
>together in order to zero them out the value just keeps fluctuating wildly.
>The fluctuation is large and happens a few times a second. If I press the
>button to zero them out it turns the meter off. I'm doing this with the
>ends of the wires off the PCB (the PCB has not been installed in the case
>yet) clamped together. Any ideas?

  John's Jukes Ltd. 2343 Main St., Vancouver, BC, Canada V5T 3C9
  Call (604)872-5757 or Fax 872-2010 (Pinballs, Jukes, Video Games)
  http://www.flippers.com
         "Old pinballers never die, they just flip out."

</x-flowed>
Received on Fri Jan 21 08:26:07 2000

This archive was generated by hypermail 2.1.8 : Tue Dec 02 2003 - 18:40:32 EST