Re: Fluke 9010a 68000 Pod Eprom TestingonOutrun- help please !!

From: Andrew Welburn <andy_at_andysarcade.net>
Date: Wed Jun 09 2010 - 18:06:35 EDT

And this is why i love my Fluke 9100A ;-)

mwuhahahhahah

--
Andrew Welburn
http://www.andys-arcade.com
----- Original Message ----- 
From: "Mike Coates" <mike@the-coates.com>
To: "Technical Tools Mail List" <techtoolslist@flippers.com>
Sent: Wednesday, June 09, 2010 10:44 PM
Subject: Re: [Techtoolslist] Fluke 9010a 68000 Pod Eprom TestingonOutrun- 
help please !!
> If a 68000 system uses 8 bit roms then they will be interleaved in the 
> memory map, hence generating the rom signature for just the 8 bit rom on 
> it's own is not going to match.
>
> I guess it either uses a different algorithm, or you need to interleave 
> the two roms, and generate the checksum for the new double sided rom.
>
> biggest pain I found with the Fluke pod is that you can only do 16 bit 
> read/writes - I had some hardware that had a custom chip that processed 32 
> bit writes, so had to 'poke' some machine code in to ram and call that to 
> do the job.
_______________________________________________
Techtoolslist mailing list
Techtoolslist@flippers.com
http://seven.pairlist.net/mailman/listinfo/techtoolslist
FTP site is: ftp://ftp.flippers.com/TTL/TestEquipment
Archive site: http://seven.pairlist.net/pipermail/techtoolslist/
Received on Wed Jun 9 18:27:04 2010