Re: Power Supply Question

From: <MKDUD_at_aol.com>
Date: Tue Jul 13 1999 - 23:33:20 EDT

In a message dated 7/12/99 11:14:43 AM Eastern Daylight Time,
matt@rossiters.com writes:

<< The power supply in my Armor Attack went out on me recently. It's the one
 by National Power Technology. It's blowing fuse F1. Is this telling me
 that my transformer is hosed or should I be looking towards the bridge
 rectifier?
>>

I'd pull the BR's and start checking them. This will cause your F1 to go,
(much higher odds of it being this than your trans..)
Received on Tue Jul 13 22:34:50 1999