> >Just an update, looked at it last night, pulled the monitor out and set it on a
> >small table next to the machine for testing. Discharged the tube, took off the HV
> >cage shield, and have not seen the problem since. The jumping has stopped, but the
> >vectors are all "crinkled". I moved the connector on the main harness that connects
> >to the AVG board and the crinkles went away. Moved them again and they came back.
> >Looks like it's time for a new connector. Could this be what was causing the
> >jumping?
>
> Most likely. Connectors are always the prime suspects when it comes
> to erratic behavior.
Well, I always figured it was the alcohol I was drinking, but.. :)
The other thing I usually do is give each individual wire a good tug to make
sure the crimp is good.
Kurt