On Mon, 18 Oct 1999, Chris Loggans wrote:
> it. What finally worked was cleaning the connector to the BU407 transistor
> mounted next to the focus and screen controls. I took the connector off,
OK -- I can try that tonight.
> If that doesn't fix it, try looking for waveforms on the legs of the 555
> timer. (Can use just a logic probe.) I've seen this cause a dead HV supply
> too.
> The only other thing I could suggest is to go through the troubleshooting
> section of Gregg Woodcock's monitor FAQ.
That's what I'm doing -- timer would be the next step. I was just wondering
it there were any other options in betwee (like cleaning the contacts of the
chasis transistor, which should have occurred to me.)
Thanks !
-Chris
==========================================================
Chris Candreva -- chris@westnet.com -- (914) 967-7816
WestNet Internet Services of Westchester
http://www.westnet.com/
Received on Mon Oct 18 15:03:22 1999
This archive was generated by hypermail 2.1.8 : Fri Aug 01 2003 - 00:32:46 EDT