I don't see that part number in mouser. I think it might be 72-T20YP-10K
Here's the catalog page if anyone cares to verify this. http://www.mouser.com/catalog/615/358.pdf
Matt
Btw - does anyone have the part numbers for the Cinematronics monitor trim pots? Are they similiar to Amplifone?
----- Original Message -----
From: MKDUD@aol.com
To: vectorlist@vectorlist.org
Sent: Wednesday, September 10, 2003 8:29 PM
Subject: Re: VECTOR: Star Wars problems
In a message dated 9/10/2003 3:33:02 PM Eastern Daylight Time, Jeff_Hendrix@maxtor.com writes:
Most of the time the screen looks normal, but sometimes (either after it's
been on for a while or sometimes when it's first turned on) the screen will
shake and very rapidly change size, but only in the x (horizontal)
direction. All horizontal lines are stable, except getting longer and
shorter. (this is why I don't think the HV unit has anything to do with it).
The output from the board looks fine on my scope (while it simultaneously
looks bad on the monitor).
This is a VERY common problem on Amplifone deflection boards. You'll want to replace the 10k X and Y size pots. I use mouser #32-1510-10k, I think they are about 60 cents each.
I wanted to add this to the REVISED deflection faq, but I'm having trouble editing the damn PDF.....
-MK
---------------------------------------------------------------------------
** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
** message body to vectorlist-request@vectorlist.org. Please direct other
** questions, comments, or problems to chris@westnet.com .
Received on Thu Sep 11 19:14:43 2003
This archive was generated by hypermail 2.1.8 : Fri Sep 12 2003 - 00:50:01 EDT