Re: Odd G08 behavior after recapping

From: Christopher X. Candreva <chris_at_westnet.com>
Date: Sat Feb 21 2004 - 13:17:52 EST

On Sat, 21 Feb 2004, Rodger Boots wrote:

> OK, THIS time actually looking at the schematics it's apparent that the
> fan is directly connected to the input power. So if part of the input
> power was missing (one side not connecting) the fan probably wouldn't
> run and the degauss circuit wouldn't shut off. The degauss circuit
> staying on would explain the twisting image you were seeing. So now the
> problem was probably in the power connector.

I had discounted that, thinking it would have meant one side (pos or neg) of
the DC supply would have been missing -- but that's wrong. It would mean
increased ripple on the DC side.

Thanks. It makes sense now.

==========================================================
Chris Candreva -- chris@westnet.com -- (914) 967-7816
WestNet Internet Services of Westchester
http://www.westnet.com/
---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Sat Feb 21 13:17:54 2004