Re: Amp blooming

From: <utahtaper_at_comcast.net>
Date: Thu Jan 19 2006 - 10:39:18 EST

With my HV probe I have adjust the voltage to 19.5KV. I have one with a Wintron that does what Tom describes his as doing.

Doesn't the original red HVT have the diode?

-------------- Original message --------------
From: "Christopher X. Candreva" <chris@westnet.com>

> On Thu, 19 Jan 2006, utahtaper wrote:
>
> > Can a Wintron fitted HVB still have blooming problems? Doesn't the Wintron
> > replace the diode that causes this? Can someone describe to me what this
> > looks like? I've searched online and found people with this problem but
> > none describe what it looks like when their monitor is doing it.
>
> Only the black & white monitors have the diode. Blooming is caused by low
> HV voltage. Have you tried adjusting the voltage ?
>
> ==========================================================
> Chris Candreva -- chris@westnet.com -- (914) 967-7816
> WestNet Internet Services of Westchester
> http://www.westnet.com/
> ---------------------------------------------------------------------------
> ** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
> ** Please direct other questions, comments, or problems to chris@westnet.com
---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Thu Jan 19 10:39:22 2006

This archive was generated by hypermail 2.1.8 : Thu Jan 19 2006 - 10:50:01 EST