Also check the trace between D901 and the HV transformer as they have been known to crack. check C916
The one with 10kv could be a bad ZD902
----- Original Message -----
From: utahtaper
To: vectorlist@vectorlist.org
Sent: Sunday, February 05, 2006 7:32 AM
Subject: VECTOR: 6100 HV help
I have been working on two HV's and both have the exact opposite problem. One has HV at 29KV's(at anode) and the other has HV at 10KV's. Both have been capped and I have been through all resistors and they are all within tolerance. Diodes have been checked and test fine. Transisters are fine. Adjusting the POT(R18? off the top of my head) does nothing to change the voltage in either case. Both display an image just one is huge(10KV) and one I'm afraid of getting X-ray(29KV) exposure to. Is there something I'm missing here? Any suggestions?
Thx,
Jason
------------------------------------------------------------------------------