Re: High Voltage Probe Usage Help

From: <andi_kraemer_at_t-online.de>
Date: Thu Feb 16 2006 - 12:53:00 EST

This link? http://www.stickycarpet.com/pinx/md.html

"Christopher X. Candreva" <chris@westnet.com> schrieb:
> On Thu, 16 Feb 2006, Tom Cloud wrote:
>
> > I'm going to give it a try to discharge a WG monitor. The monitor is OUT
> > of the game and on the workbench. I'm assuming that aligator clip will
> > connect to ground somewhere. Can anyone suggest where I might connect this
> > clip to? All FAQ's I've read say to connect it to chassis, but since the
> > monitor is not in the game, the monitor chassis is not currently grounded
> > - hense my ?
>
> There was a big web page written up on this and I don't recall the link.
> Think of the tube as a big capacitor, or battery. You are putting a load
> across it to drain it out.
>
> So the chasis ground is correct because you are measureing, draining it's
> internal voltage. You do NOT want to connect it to the actual earth ground,
> and definately NOT the AC outlet ground.
>
>
> ==========================================================
> Chris Candreva -- chris@westnet.com -- (914) 967-7816
> WestNet Internet Services of Westchester
> http://www.westnet.com/
> ---------------------------------------------------------------------------
> ** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
> ** Please direct other questions, comments, or problems to chris@westnet.com
>

---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Thu Feb 16 12:53:28 2006

This archive was generated by hypermail 2.1.8 : Fri Feb 17 2006 - 13:50:01 EST