true but then amplifone could have given insulation breakdown figures....in
real life they wouldn't have been anywhere close because of the poor potting
materials
----- Original Message -----
From: "peter jones" <highwayman2000@mail.ru>
To: <vectorlist@vectorlist.org>
Sent: Wednesday, August 23, 2006 9:48 AM
Subject: VECTOR: Re[2]: VECTOR: Amplifone replacement is here!!
>
> -----Original Message-----
> From: "simon" <simonjhanlon@btopenworld.com>
> To: <vectorlist@vectorlist.org>
> Date: Wed, 23 Aug 2006 07:14:00 +0100
> Subject: Re: VECTOR: Amplifone replacement is here!!
>
>> Out of interest I will set one up on the bench and drive it to see how
>> much voltage/current it will give before failing, I can only measure up
>> to 40KV but I'm sure that's high enough
>>
> i'm not sure there would be any point overvoltage testing,
> the mfr could tell us what the insulation breakdown voltage is on the wire
> but in use the voltage would not rise.
>
> testing current and maybe maximum frequency may be more interesting
> though.
>
> ---------------------------------------------------------------------------
> ** Unsubscribe, subscribe, or view the archives at
> http://www.vectorlist.org
> ** Please direct other questions, comments, or problems to
> chris@westnet.com
>
>
> --
> No virus found in this incoming message.
> Checked by AVG Free Edition.
> Version: 7.1.405 / Virus Database: 268.11.4/424 - Release Date: 8/21/2006
>
>
---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Wed Aug 23 14:57:45 2006
This archive was generated by hypermail 2.1.8 : Wed Aug 23 2006 - 15:50:02 EDT