Ok...getting warmer here. According to NTE, their capacitor has a rating better than the Z5F rating called for except for the Temperature coefficient. Mine is 10% and the specified value is 7%. Will this be a problem? -Malcolm
Malcolm Mackenzie <maxstang@sbcglobal.net> wrote: Ok...so I'm displaying my ignorance here. Rebuilding my HV unit and want to replace a burned disc capacitor at C913. The manual states it's a .001 micro farad type ZDF capacitor. Is that different than a regular ceramic disc capacitor? From my online reading the ZDF means that it operates at spec within a given temperature range for this marking. I have a NTE 1KV capaictor with the right capacitance, but it doesn't say anything about it's operating range. Can anyone enlighten me? -Malcolm
---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Sun Jul 1 17:18:33 2007