Re: TEMPEST update

From: <fredk_at_mchsi.com>
Date: Mon Jun 09 2008 - 11:58:25 EDT

Hey Roger been awhile since I've heard from you.. You still in CR?

---------------------- Original Message: ---------------------
From: Rodger Boots <rlboots@cedar-rapids.net>
To: vectorlist@vectorlist.org
Subject: Re: VECTOR: TEMPEST update
Date: Mon, 9 Jun 2008 07:06:14 +0000

>
>
> vernimark@vernimark.com wrote:
> > Hi all,
> > I tested HV with my HW probe and I can understand that HV
> > goes from 19.5 to 20.1 kv. when HV reach 20.1 then the
> > screen become dark.
> >
> > Is it normal that during normal operation I've a range (19.5
> > - 20.1 Kv) so large?
>
> Seems like a reasonable range to me. The voltage is going up because
> you're loosing brightness, not the other way around.
>
> You're loosing brightness because, most likely, the screen supply from
> the screen/G2 pot is dropping OR grid 1 is drifting negative due to a
> bad connection.
> ---------------------------------------------------------------------------
> ** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
> ** Please direct other questions, comments, or problems to chris@westnet.com
---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Mon Jun 9 11:58:31 2008

This archive was generated by hypermail 2.1.8 : Mon Jun 09 2008 - 21:50:00 EDT