Re: Tempest shimmer

From: Kirk Spradling <kspradling_at_kc.rr.com>
Date: Mon Mar 28 2011 - 06:33:01 EDT

Oops... I can't type... C905 instead of C903...
  ----- Original Message -----
  From: Kirk Spradling
  To: vectorlist@vectorlist.org
  Sent: Monday, March 28, 2011 5:20 AM
  Subject: Re: VECTOR: Tempest shimmer

  My Tempest lost the 2N3792 in the low voltage power supply and it took out the corresponding cap in HV cage. Lines looked almost like an EKG. When I removed the cage, C902 was blown apart. Replace C901, C902 and C903.

  How long since a cap kit?

  Kirk S.

  P.S. the 6100_faq has info on various problems...
    ----- Original Message -----
    From: Kevin Moore
    To: vectorlist@vectorlist.org
    Sent: Monday, March 28, 2011 2:30 AM
    Subject: Re: VECTOR: Tempest shimmer

    Is the high voltage cage missing?

    On Mon, Mar 28, 2011 at 1:05 AM, David Shoemaker <davids@oz.net> wrote:

      I have a tempest which is working fine except that the lines shimmer noticeably.

      I have adjusted bip / lin / x&Y size and center. Everything looks good but the lines are just not completely stable.

      I am guessing something in the HV needs to be adjusted / replaced but I don’t want to just shotgun it.

      Suggestions?

      David

---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Mon Mar 28 06:33:47 2011