Check the polarity of the z axis blanking signal. You may need to invert it.
Sent from my iPhone
On Oct 3, 2011, at 10:07 AM, Douglas Gauck <douglas@gauck.com> wrote:
> It may be simple for David but I can't seem to get either of my scopes (Tek 475A and 2465B) to pay enough attention to the Z signal to blank the repositioning vectors. There is a barely perceptible decrease in intensity when I hook it up but they're still visible. What's the proper way to connect for blanking?
>
> -Douglas
>
>
> On Oct 3, 2011, at 1:06 AM, "David Shoemaker" <davids@oz.net> wrote:
>
>> I am benching testing a couple of tempest boards on my Scope and have lots of retrace vectors cluttering up the display.
>>
>>
>>
>> When doing a BZ it is simple to hook up the z input of the scope to the intensity signal and get a pretty good picture.
>>
>>
>>
>> BUT of course on tempest there are 3 intensities. Has anyone ever come up with a nice simple circuit to build a unified intensity channel for this kind of use?
>>
>>
>>
>> Thanks,
>>
>> David
---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Mon Oct 3 10:35:46 2011
This archive was generated by hypermail 2.1.8 : Mon Oct 03 2011 - 11:50:01 EDT