Re: Adjusting K6100 (tempest) HV / b+

From: Mark Shostak <shostakmark_at_gmail.com>
Date: Sat Oct 08 2011 - 20:22:55 EDT

Check both sides of the pass transistor (make sure the rail is nominal)

Check the Zener

Check the parts between the Zener and the pass trani

On Sat, Oct 8, 2011 at 7:11 PM, David Shoemaker <davids@oz.net> wrote:

> I just recapped a HV unit on a tempest. In the process I replaced Q901
> (MSPA06) and R904 (470 1/2w).****
>
> ** **
>
> The monitor turns on and has a reasonable display.****
>
> ** **
>
> BUT: My B+ voltage is 56v (checked at Pin 5 of the J900). I can’t find my
> HV probe to check what the HV is at right now.****
>
> ** **
>
> The pot on the HV board doesn’t make any difference to the b+ voltage.****
>
> ** **
>
> Before I start to just shotgun parts (R918 the adjustment pot, Q902, Q903)
> anyone have any suggestions?****
>
> ** **
>
> Thanks,****
>
> David****
>
> ** **
>

---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Sat Oct 8 20:23:16 2011