Another K6100 HV question

From: David Shoemaker <davids_at_oz.net>
Date: Sun Oct 09 2011 - 01:05:33 EDT

As I was on a roll I figured I would take a crack at another of my HV units.

 

No stable HV, B+ is shifting around.

 

I traced back to Q900 (BU409) and found it to have bad voltages (+ / - 26V
on all three legs). Figured it was shorted so replaced it with a known
good.

 

Turned the monitor on and got HV crackle, YAY I thought. Then I heard snap
and smelled the magic smoke. BOO.

 

BU409 now giving the same values as before.

 

I have recapped the HV and replaced Q901, 902.

 

 

Anyone have a reasonable source for BU409's? And any ideas of what is
blowing them?

 

And while I am at it, source for the 150V 1w zeners?

 

Thanks,

David

---------------------------------------------------------------------------