1:
HVT with a cinelabs HV unit installed.
Good +/- 24 V
Good crackle / HV.
No neck glow, testing the heater voltage at the back of the board I am
getting ~ 13.0v AC. Roughly double what I would expect. This tube was
working fine with the last HV I worked on but I don't have a known good at
the moment to verify something didn't go bad there. I did continuity test
the tube heater pins and that seems fine.
2:
HVT with a Red transformer (yea I know, red = dead).
I don't have a ringer handy to test it with.
Good -24
Bad +24 (reads around +12), I pulled the 406D out and retested, the +24 was
there.
Putting the 406D back in and replaced the LM7824, no change.
Suggestions?
Thanks,
David
---------------------------------------------------------------------------