Re: Gorf & Targ

From: Marlin Bates, IV <mcb242_at_psu.edu>
Date: Mon Sep 08 2003 - 02:53:43 EDT

Thanks. I checked both (they are both Electrohome G07) and both are
getting 120VAC and all fuses check out good.

Next? :-)

On Sunday, September 7, 2003, at 11:36 PM, peter jones wrote:

> -----Original Message-----
> From: Marlin Bates <mcb242@psu.edu>
> To: rasterlist@vectorlist.org
> Date: Sun, 7 Sep 2003 20:25:01 -0700
> Subject: RASTER: Gorf & Targ
>
>>
>> Hello folks,
>>
>> I just picked up a Gorf and a Targ. Both play blind with no picture.
>> There is no neck glow on the tubes. All fuses look good. Any
>> suggestions?
>>
>> Thanks
>>
>> -Marlin
>>
> start with the basics, put a meter on the monitor power connectors and
> see if you get 100-120v ac.
>
> if you do then look on the monitors for fuses,
> post the monitor make/model if you reply to this - and if they are
> wells-gardner 4600 style with vertical pcb's then you need to remove
> the base pcb and resolder all the sockets.
>
> -----------------------------------------------------------------------
> ----