Alternatively just disable the force line error in the Fluke setup.
For the 9010A there is a SETUP key on the keyboard.
Press that one and then MORE until you see Force Line and then enter NO.
-Andreas
-----Ursprüngliche Nachricht-----
From: Mark Templeton
Sent: Tuesday, May 28, 2013 11:31 PM
To: rasterlist@vectorlist.org
Subject: RASTER: Gorf troubleshooting with Fluke
Does anyone have a quick fix for stopping the watchdog reset on a Midway
Card Rack system (Gorf in particular)? I get the usual Force Line
problem, but whereas on a Williams board I'd cut a track, or on an Atari
board fit the appropriate jumper, I assume that a Gorf should need a
specific location programmed to enable/disable watchdog. Any ideas?
Mark
---------------------------------------------------------------------------