Re: Fluke 9010a + z80 pod questions

From: John Robertson <jrr_at_flippers.com>
Date: Thu Sep 06 2001 - 14:56:13 EDT

<x-flowed>
Perhaps the Arkanoid has an incorrect setup for the CPU. Check with the Z80
docs on what the CPU needs, and then check with the pod book to see what
the Fluke requires. You might find that instead of using a pull-up that
Taito just hardwired Halt to Vcc for example.

John :-#)#

At 11:35 AM 9/06/01, you wrote:

>I tried another Arkanoid board (that has problems) and got the same
>error. But then I tried a Dig Dug board and that one worked fine. So
>the pod is good, just something it doesn't like about the Arkanoid
>board. Maybe it's clock signal is really noisy?
>
>Thanks again for your help.
>
>-Werner
>
>
>To UNSUBSCRIBE from techtoolslist, send a message with "UNSUBSCRIBE" in the
>message body to: techtoolslist-request@flippers.com. Please direct other
>questions, comments, or problems to jrr@flippers.com.
>
>

</x-flowed>
Received on Thu Sep 06 12:21:29 2001