RE: Bad monitor discharge instructions

From: Fish, David <dfish_at_bev.etn.com>
Date: Mon Dec 20 1999 - 11:22:50 EST

> From: Mark Spaeth [mailto:mspaeth@arcade.ne.mediaone.net]
> Sent: Monday, December 20, 1999 11:03 AM
> To: vectorlist@lists.cc.utexas.edu
> Subject: Re: Bad monitor discharge instructions
>
> so E = Q * V = C * V^2...
>
> So assuming your .001 F measurement is correct, and using V=20,000
> E = 400,000J Hmmm... that'll keep you warm at night...
>

Hey Mark,

Jeez, you take the 'mit' out of your address and you automatically
became less smart ;-) ;-)

John's measurement was 0.001uF, the 102 was the giveaway. This
gives you 0.4J. The math is left to the student.

Dave