Re: AR 2 bench testing

From: John Robertson <jrr_at_flippers.com>
Date: Mon May 28 2001 - 23:08:57 EDT

That is a very light load - only about 200ma @ 5VDC, I use a 1 ohm 25 to 50
watt resistor as a load for testing powers supplies. That is 1 amp @ 5VDC,
and is a reasonable load for any power supply. I think it would be good to
just short the sense resistors out, as they only seem good to burn up, and
you can adjust the supply manually for the correct voltage.

John :-#)#

At 02:22 AM 28/05/2001, you wrote:
>What's a good sized load to use when testing these? I have been using a
>22ohm 5W from +5 to Gnd. +Sense tied to +5 -Sense tied to Gnd.
>
>Reasonable?
>
>
>Also what do you think of the idea of tying the sense's to there
>respective values at the AR2. Keep them from burning up the sense
>resistors quite so easily, though I realize it will pretty much disable
>the wire harness loss sensing.
>
>
>Open to tomato's.
>
>
>David
>

---------------------------------------------------------------------------