Re: Question regarding 19K6100 HV Transformer....

From: Gregg Woodcock <woodcock_at_sisna.com>
Date: Tue Sep 10 2002 - 23:43:14 EDT

----- Original Message -----
From: "Stempak Arcadius-ASTEMPA1" <ASTEMPA1@motorola.com>
To: <vectorlist@synthcom.com>
Cc: "Stempak Arcadius-ASTEMPA1" <ASTEMPA1@motorola.com>
Sent: Tuesday, September 10, 2002 3:36 PM
Subject: RE: VECTOR: Question regarding 19K6100 HV Transformer....

> Greg,
> ^^^^^
>
> Thank you once again, appreciate the
> information and have one last question on
> this Topic, if you do not mind.
>
> Since my MAX HV Output only goes up to 17.8 KV
> Yet the monitor appears to function normally,
> from what I can tell at around 16.2KV should I
> set the 25K Pot in the HV Cage to MAX, which would
> then more or less bring the HV to almost the
> reccomended 19.5KV as stated in the Wells Gardner
> Vector Manual or should I just leave things alone ???

Set the B+ voltage (orange wire, I believe) to 180VDC (I think that is the
correct voltage; better double check what the schematics say for B+) by
adjusting that pot. Then the HVT control should be in suitable range.

---------------------------------------------------------------------------
** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
** message body to vectorlist-request@synthcom.com. Please direct other
** questions, comments, or problems to vectorlist-owner@synthcom.com.
Received on Tue Sep 10 21:03:29 2002