Re: HV transformers - help!

From: <A218_at_aol.com>
Date: Sat Sep 28 2002 - 09:22:18 EDT

In a message dated 9/28/02 12:09:13 AM Eastern Daylight Time,
highwayman2000@mail.ru writes:

<< - can someone who has a G08 (and knows what they are doing) please wind
the voltage down to 19.5 KV and report any problems with the image. >>

Can the HV be reduced without reducing the overall B+ level in the monitor?
I am not familiar with the G08, but in most TV and monitor circuits, HV
reduction is accomplished by reducing the DC level coming out of the
regulator.

If the overall B+ level is reduced there may be some size issues with the
monitor that would appear.
 

Art
---------------------------------------------------------------------------