I have a HV probe,
 its what i used to discharge the monitor, so i could re-cap it. What
voltage should i set it to ?

Pinx

p.s. Col, any parts you have would be much appreciated, also nice to see
you got the ESB working :)

----- Original Message -----
From: "Christopher X. Candreva" <chris@westnet.com>
To: <vectorlist@vectorlist.org>
Sent: Friday, April 01, 2005 8:22 PM
Subject: Re: VECTOR: SW monitor prob...

> On Fri, 1 Apr 2005, Pinx wrote:
>
>> "blooming" and so i have just re-capped the HV section, but i still have
>> the problem. Is there anything else on the HV board i should replace to
>> cure this problem ?
>
> Re-capping isn't really a fix for blooming. Blooming comes from voltage
> in
> the HV section. The simple way to check that is with a HV probe, which can
> be had for under $20 on e-bay usually.
>
> If it is low, it can be adjusted, the pot may have just slipped.
>
> ==========================================================
> Chris Candreva -- chris@westnet.com -- (914) 967-7816
> WestNet Internet Services of Westchester
> http://www.westnet.com/
> ---------------------------------------------------------------------------