I measured at the board and found -21 volts at the X test point and found 13 volts at the Y. What would cause this? Can I assume the board is jacked and send it for repair?
----- Original Message -----
From: Rodger Boots
To: vectorlist@vectorlist.org
Sent: Monday, September 26, 2005 12:43 AM
Subject: Re: VECTOR: Red Baron issues
utahtaper wrote:
Is it typical for a boardset to take out a monitor? My Red Baron seemed to have taken out chassis mounted transisters on my working monitor. I'm afraid to plug it back in for testing since I fixed it. Is this typical? What causes this?
----------------------------------------------------------------------------
No virus found in this outgoing message.
Checked by AVG Anti-Virus.
Version: 7.0.344 / Virus Database: 267.11.6/111 - Release Date: 09/23/2005
Typical, no. Could it happen, you betcha!
Run the game WITHOUT the monitor and measure the X and Y outputs at the monitor connector to ground. They should measure around 0 volts plus or minus a volt and will change slightly as the picture would be changing. If you get something like 5 volts, you definitely have a problem.
------------------------------------------------------------------------------
No virus found in this incoming message.
Checked by AVG Anti-Virus.
Version: 7.0.344 / Virus Database: 267.11.6/111 - Release Date: 09/23/2005
No virus found in this outgoing message.
Checked by AVG Anti-Virus.
Version: 7.0.344 / Virus Database: 267.11.6/111 - Release Date: 09/23/2005
---------------------------------------------------------------------------