Following up:
This is a P329 version board (with the HV cutoff), deflection has a LV2000
in it, the HV input at P900 is +/- 26v which is a bit low for the reference
values, I am keeping that in mind.
I have replaced:
Q901 & Q902 (MPSA06)
Q903 (2n3904)
Q900 (with a BU406D)
ZD901 (1n4743)
All the caps
I am getting HV (crackle, but can't find my HV probe to verify what it is
at).
B+ is 216v and adjusting the pot doesn't make any difference. From the FAQ
I have gone through everything it suggests for all the no effect:
Verified R912, R902 & R915 in circuit values all seem correct.
I have checked R901 - 906 in circuit and all seem ok.
Game in self-test.
At R904 where it connects to Q901 & Q902 the schematic says 6.9v I am
getting 23.1.
At Q900:
Base (reference 6.5) I get 14.5
Emitter (ref 6.0) I get 13.9
Collector is ~ 25v (close to right)
At ZD902 (150v zener) the reference is 33.7 and I have 57. The other side
which should be 181 is 216.
Voltages near Q906 (the BU207) are all within reasonable given the slightly
lower input voltages.
I was thinking possibly D901 or D902 is bad but I don't know what to replace
it with. I saw a reference to FR156 (which is only available from bob
Roberts) are there any other suggestions for replacing the ERC27-13?
Anyone know if I am totally off base here?
Thanks,
David
From: owner-vectorlist@vectorlist.org
[mailto:owner-vectorlist@vectorlist.org] On Behalf Of David Shoemaker
Sent: Sunday, October 09, 2011 2:41 PM
To: vectorlist@vectorlist.org
Subject: RE: VECTOR: Another K6100 HV question
Good page, I dug around on it a bit and noticed your also missing a source
for Q905 (2n6557 obsolete). As far as I can see the suggested replacement
is MJE15030 but it requires either a board mod or leg crossing.
And BU207 (Q906).
From: owner-vectorlist@vectorlist.org
[mailto:owner-vectorlist@vectorlist.org] On Behalf Of William Boucher
Sent: Sunday, October 09, 2011 9:23 AM
To: vectorlist@vectorlist.org
Subject: Re: VECTOR: Another K6100 HV question
Lots of good folks already answered your question but just in case...
I have a list of replacement parts for the wg6100 on a webpage here:
http://www.biltronix.com/arcade_electcomp_01.html#wg6100_rebuild_parts
This list includes the 150V zener as this
http://search.digikey.com/scripts/DkSearch/dksus.dll?Detail?name=1N5383BRLGO
SCT-ND
Looks like I neglected to show a source for Q900. I'll have to fix that.
William Boucher
http://www.biltronix.com
----- Original Message -----
From: David Shoemaker <mailto:davids@oz.net>
To: vectorlist@vectorlist.org
Sent: Sunday, October 09, 2011 1:05 AM
Subject: VECTOR: Another K6100 HV question
As I was on a roll I figured I would take a crack at another of my HV units.
No stable HV, B+ is shifting around.
I traced back to Q900 (BU409) and found it to have bad voltages (+ / - 26V
on all three legs). Figured it was shorted so replaced it with a known
good.
Turned the monitor on and got HV crackle, YAY I thought. Then I heard snap
and smelled the magic smoke. BOO.
BU409 now giving the same values as before.
I have recapped the HV and replaced Q901, 902.
Anyone have a reasonable source for BU409's? And any ideas of what is
blowing them?
And while I am at it, source for the 150V 1w zeners?
Thanks,
David
---------------------------------------------------------------------------