Re: FLUKE 9100A SERIES QUESTION

From: AL SACCO <asacco007_at_hotmail.com>
Date: Mon Nov 29 2010 - 03:52:41 EST

I only attached pods when power was off ....

John Robertson <jrr@flippers.com> wrote:

>AL SACCO_hm wrote:
>> HELP FOR FLUKE 9100 USER
>>
>> Need some help on an issue that has happened during power up on multiple Fluke 9100a or ft units that I tested....
>> if no pod is attached to 9100 during it comes up "no pod connected".....
>> if any pod is attached it comes up "enabled line caused timeout"
>> any idea or help would be helpful.....
>>
>> AL SACCO
>> _______________________________________________
>>
>
>As I recall you can't hook up a pod while the power is on, only when off...
>
>John :-#)#
>
>--
>John's Jukes Ltd. 2343 Main St., Vancouver, BC, Canada V5T 3C9
>Call (604)872-5757 or Fax 872-2010 (Pinballs, Jukes, VideoGames)
> www.flippers.com
>"Old pinballers never die, they just flip out"
>
>_______________________________________________
>Techtoolslist mailing list
>Techtoolslist@flippers.com
>http://seven.pairlist.net/mailman/listinfo/techtoolslist
>FTP site is: ftp://ftp.flippers.com/TTL/TestEquipment
>Archive site: http://seven.pairlist.net/pipermail/techtoolslist/
>
_______________________________________________
Techtoolslist mailing list
Techtoolslist@flippers.com
http://seven.pairlist.net/mailman/listinfo/techtoolslist
FTP site is: ftp://ftp.flippers.com/TTL/TestEquipment
Archive site: http://seven.pairlist.net/pipermail/techtoolslist/
Received on Mon Nov 29 03:57:38 2010