Hi All,
Well, I'm back again with another tempest problem (you see,
I bought the game to work and it is on _all_ the time).
This is the second failure in about two months. Last time
I burnt Q901, and R903. Replaced both of them and put in a
Bob Roberts cap/upgrade/reliability kit (though I only
installed the HV part). Monitor does have an LV2000
installed.
Anyway, I came in a couple of week ago and the HV was gone
again. I finally pulled the monitor yesterday and found
that R901 was open. Replaced it, got HV back but now every
vector is severely jagged and R901 is running hot (it
started to smell shortly after powering up, another 30
seconds and it would have burnt open).
A while back I posted that my HV cage ticks. I was hoping
the work I did before would fix that but it still ticks and
I was wondering if this could be related.
Any help greatly appreciated. Thanks very much.
Dan Rasmussen
PS Joel, you have to stop by some time, I'm only five mins
away from HP these days (Methuen).
=====
------ replies to sscanf@yahoo.com ------