I believe Wintron wants you to change R11 to a 1k resistor. This is for
reliability and not necessary.
To resolve the HV, try changing R6 to a 4.7k. Sometimes you do need to
change it's value slightly.........
JB
lingland wrote:
> Another amplifone question here...I replaced my dead read with a
> Wintron, and I thought all was well, but I just cannot seem to pull my
> focus enough to get my screen to be real clear. I tested my output
> voltage, and I see that with my R7 fully open, I get 19K, not
> 19.5KShouldn't with R7 fully open I get >>> 19K? Is my next step to
> verify my pot is good, or is there something else for me to
> check? Thanks,Rob
---------------------------------------------------------------------------